Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1987 1
1989 1
1990 1
1995 1
1998 1
2004 1
2005 2
2009 1
2011 5
2012 5
2013 3
2014 2
2015 5
2016 5
2018 2
2019 2
2020 2
2021 1
2022 5
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

43 results

Results by year

Filters applied: . Clear all
Page 1
Self-aligning roly-poly RFID tag.
Dobrykh D, Yusupov I, Ginzburg P, Slobozhanyuk A, Filonov D. Dobrykh D, et al. Sci Rep. 2022 Feb 8;12(1):2140. doi: 10.1038/s41598-022-06061-6. Sci Rep. 2022. PMID: 35136164 Free PMC article.
Radio frequency identification (RFID) is a mature technology that allows contactless data readout via a wireless communication link. ...Our tag is made of a high permittivity ceramic resonator, inductively coupled to a metal ring, which contains an RFID chip.
Radio frequency identification (RFID) is a mature technology that allows contactless data readout via a wireless communication lin
Automatic frequency controller for power amplifiers used in bio-implanted applications: issues and challenges.
Hannan MA, Hussein HA, Mutashar S, Samad SA, Hussain A. Hannan MA, et al. Sensors (Basel). 2014 Dec 11;14(12):23843-70. doi: 10.3390/s141223843. Sensors (Basel). 2014. PMID: 25615728 Free PMC article. Review.
Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sid …
Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, re …
A fully implantable rodent neural stimulator.
Perry DW, Grayden DB, Shepherd RK, Fallon JB. Perry DW, et al. J Neural Eng. 2012 Feb;9(1):014001. doi: 10.1088/1741-2560/9/1/014001. Epub 2012 Jan 17. J Neural Eng. 2012. PMID: 22248468 Free PMC article.
We developed a fully implantable neural stimulator that is able to deliver two channels of intra-cochlear electrical stimulation in the rat. It is powered via a novel omni-directional inductive link and includes an on-board microcontroller with integrated radio
We developed a fully implantable neural stimulator that is able to deliver two channels of intra-cochlear electrical stimulation in the rat. …
In-Vitro Demonstration of Ultra-Reliable, Wireless and Batteryless Implanted Intracranial Sensors Operated on Loci of Exceptional Points.
Yang M, Ye Z, Alsaab N, Farhat M, Chen PY. Yang M, et al. IEEE Trans Biomed Circuits Syst. 2022 Apr;16(2):287-295. doi: 10.1109/TBCAS.2022.3164697. Epub 2022 May 19. IEEE Trans Biomed Circuits Syst. 2022. PMID: 35380967
Here, we seek to address this long-existing challenge and to robustly acquire information from a passive wireless intracranial pressure (or brain pressure) sensor by introducing a novel, high-performance biotelemetry system. In spite of variable inductive links, this biote …
Here, we seek to address this long-existing challenge and to robustly acquire information from a passive wireless intracranial pressure (or …
A 21.3%-Efficiency Clipped-Sinusoid UWB Impulse Radio Transmitter With Simultaneous Inductive Powering and Data Receiving.
Soltani N, Jafari HM, Abdelhalim K, Kassiri H, Liu X, Genov R. Soltani N, et al. IEEE Trans Biomed Circuits Syst. 2022 Dec;16(6):1228-1238. doi: 10.1109/TBCAS.2022.3225304. Epub 2023 Feb 14. IEEE Trans Biomed Circuits Syst. 2022. PMID: 36445989
An ultra-wide-band impulse-radio (UWB-IR) transmitter (TX) for low-energy biomedical microsystems is presented. ...A new clipped-sinusoid scheme is proposed for on-off keying (OOK)-modulation, which is implemented by a voltage clipper circuit with on-chip biasing generatio …
An ultra-wide-band impulse-radio (UWB-IR) transmitter (TX) for low-energy biomedical microsystems is presented. ...A new clipped-sinu …
An Inductively Powered Implantable System to Study the Gastrointestinal Electrophysiology in Freely Behaving Rodents.
Berry DT, Choi J, Dexheimer CA, Verhaalen MA, Javan-Khoshkholgh A. Berry DT, et al. Bioengineering (Basel). 2022 Oct 6;9(10):530. doi: 10.3390/bioengineering9100530. Bioengineering (Basel). 2022. PMID: 36290498 Free PMC article.
The system consists of a miniature-sized implantable unit (IU), a stationary unit (SU) that communicates with the IU over a 2.4 GHz far-field radio frequency (RF) bidirectional link, and a charging unit (CU) that establishes an inductive 13.56 MHz near-field …
The system consists of a miniature-sized implantable unit (IU), a stationary unit (SU) that communicates with the IU over a 2.4 GHz far-fiel …
An Extended-Range Inductive Near-Field Telemetry System for High-Resolution Mapping of Gastrointestinal Activity().
Javan-Khoshkholgh A, Farajidavar A. Javan-Khoshkholgh A, et al. Annu Int Conf IEEE Eng Med Biol Soc. 2020 Jul;2020:4217-4220. doi: 10.1109/EMBC44109.2020.9176349. Annu Int Conf IEEE Eng Med Biol Soc. 2020. PMID: 33018927
The WU transfers power to the IU and recharges its battery through an inductive link, wirelessly; and over the same link, reads the 64-channel slow waves data encoded by a differential pulse position coding algorithm, which is modulated through a load shift-k …
The WU transfers power to the IU and recharges its battery through an inductive link, wirelessly; and over the same link
Performance of a radio link between a base station and a medical implant utilising the MICS standard.
Johansson AJ. Johansson AJ. Conf Proc IEEE Eng Med Biol Soc. 2004;2004:2113-6. doi: 10.1109/IEMBS.2004.1403620. Conf Proc IEEE Eng Med Biol Soc. 2004. PMID: 17272140
Modern medical implants are of increasing complexity and with that, the need for fast and flexible communication with them grows. A wireless system is preferable and an inductive link is the most commonly used. But it has the drawback of a very short range, essentia …
Modern medical implants are of increasing complexity and with that, the need for fast and flexible communication with them grows. A wireless …
An Implantable RFID Sensor Tag toward Continuous Glucose Monitoring.
Xiao Z, Tan X, Chen X, Chen S, Zhang Z, Zhang H, Wang J, Huang Y, Zhang P, Zheng L, Min H. Xiao Z, et al. IEEE J Biomed Health Inform. 2015 May;19(3):910-9. doi: 10.1109/JBHI.2015.2415836. Epub 2015 Mar 23. IEEE J Biomed Health Inform. 2015. PMID: 25823049
This paper presents a wirelessly powered implantable electrochemical sensor tag for continuous blood glucose monitoring. The system is remotely powered by a 13.56-MHz inductive link and utilizes an ISO 15693 radio frequency identification (RFID) standard for …
This paper presents a wirelessly powered implantable electrochemical sensor tag for continuous blood glucose monitoring. The system is remot …
43 results